Home /Products /Gold Extraction /Desorption Electrolysis System
Desorption Electrolysis System

Desorption Electrolysis System

[Introduction]: Desorption electrolysis system as gold extraction equipment obtains gold mud from carbon by desorption and electrowinning

[Capacity]: 3.5kg/t

[Improvement]: Desorption electrolysis system consists of electrolysis equipment including desorption column and the electrodeposition tank

Advantages

In the high temperature (150℃) and pressure (0.5MPa), the desorption rate reaches 98%;

Since desorption and electrolysis does not require different temperatures, it is not necessary to change temperature;

The quickness and efficiency of machine dramatically diminishes gross electricity consumption by 1/2-1/4;

Desorption does not require sodium cyanide, which reduces cost and averts pollution.

Product Structure

Separation-Drawing-of-High-Efficiency

Desorption Electrolysis System principle

In gold electrowinning process,when the electrolysis equipment is added with anions that are more easily absorbed by activated carbons, Au(CN)2ˉ is replaced by anion and the gold desorption is achieved. After the carbons loaded with gold are desorbed, pregnant solutionprocesses thevia ionization. At last, the solid gold is attained.

Technical Parameters

ModelSuitable ScaleSystem    Equipment ListSystem Instrument ListOperation    Parameters
Mine Scale (t/d)Raw  Ore Grade (g/t)
GJD-200< 1502~8

$1 Desorption Column

$2 Filter

$3 Electrolytic Tank

$4 Circulating Pump

$5 Electric Heater

$6 Carbon Ejector

$7 Air Compressor

$8 Desorption Solution Tank

$9 Clarified Water Pump

$10 Acid Storage Tank $11 Magnetic Pump

$12 Carbon Storage Tank

$15 Control Cabinet

$16 Silicon Rectifier Cabinet

$17 Pickling Tank

B1 Electric Resistance Remote Transmission    Diaphragm-Seal Pressure Gauge

B1    Pressure Indication Adjusting Meter

B2 Diaphragm Pressure Gauge

B3 Vortex Shedding Flowmeter

B3 Flow Integrating    Instrument

B4 Thermal Temperature Meter

B5    Temperature Sensor

B5 Temperature IndicationAdjusting    Meter

P6 Diaphragm Pressure Gauge

B7 Level Meter

B9    Temperature Sensor

B9 Temperature Indication Adjusting Meter

Desorption    Solution:

PH > 13.5
 Time    of Application:

Infinite
 Electrolysis    Start:

100-110°C

Electrolysis    Ending:
 150°C

Electrolysis    Current:

350-1250A

Electrolysis Pressure:

2-4V
 Pressure    at

150C :
Upper    of Desorption Column:

0.50-0.57MPa

Electrolytic Tank:

0.45-0.52MPa

GJD-300150~300
GJD-450
GJD-500300~500
GJD-600
GJD-750
GJD-1000500~1000
GJD-1200
GJD-1500
GJD-1800
GJD-20001000~2000
GJD-2500
GJD-3000
GJD-35002000~30002~20
GJD-4000
GJD-5000
Especial> 3000

Related Products